Instrumented Piles Tested in 1969 in Fine Loose Sand at Holmen, Drammen: Revisited 2019
作者: A.S. Balasubramaniam E. Oh G. Chao H. Kim R. N. Hwang
刊名: Geotechnical Engineering Journal of the SEAGS & AGSSEA, 2019, Vol.50 (4)
来源数据库: Southeast Asian Geotechnical Society (SEAGS)
关键词: Pile load testBearing capacityPull out test
原始语种摘要: The work presented here relates to the instrumented piles tested in 1969, by the Norwegian Geotechnical Institute (NGI) in loose sand at Holmen, Drammen. The material contained in the first publication, which is an Internal Report F.273.0 of NGI (Balasubramaniam et al., 1969), was mainly on the load tests only and contained the analyses of the vibrating wire gauges as based on the zero of the gauges after the pile driving, to make sure the best set of zero values were used. The publication of Gregersen et al. in 1969, includes pull out tests and also the effect of the residual stresses developed in the piles during pile driving. Further, the work of Gregersen et al. contains a detail section on the performance of the vibrating wire gauges and in particular the drifting of the zero of the...