Hysteroscopic Tissue Removal Systems: A Randomized In Vitro Comparison
作者: Deidre MeulenbroeksTjalina W.O. HamerlynckSema Saglam-KaraNadia K. Van RijsselHuib A.A.M. Van VlietBenedictus C. Schoot
作者单位: 1Department of Obstetrics and Gynecology, Catharina Hospital, Eindhoven, The Netherlands
2Women's Clinic, Ghent University Hospital, Ghent, Belgium
3Utrecht University, Utrecht, The Netherlands
刊名: The Journal of Minimally Invasive Gynecology, 2017, Vol.24 (1), pp.159-164
来源数据库: Elsevier Journal
DOI: 10.1016/j.jmig.2016.08.829
关键词: Hysteroscopic morcellationHysteroscopyMyomaPolyp
英文摘要: Abstract(#br)Study Objective(#br)To compare polyp resection time and myoma resection rate using 2 hysteroscopic tissue removal systems.(#br)Design(#br)Prospective randomized in vitro trial (Canadian Task Force classification I).(#br)Setting(#br)Clinical skills laboratory of a non-university teaching hospital.(#br)Samples(#br)Polyp surrogate and myoma tissue.(#br)Interventions(#br)Hysteroscopic tissue removal with the TRUCLEAR system, using the TRUCLEAR INCISOR 2.9 (TI), TRUCLEAR INCISOR Plus (TIP), or TRUCLEAR ULTRA Plus (TUP) device, and the MyoSure system, using the MyoSure Lite (ML), MyoSure Classic (MC), or MyoSure XL (MXL) device.(#br)Measurements and Main Results(#br)Forty-two fragments of umbilical cord weighing 5 g, as a surrogate for polyps, were randomly allocated to 4 types of...
全文获取路径: Elsevier  (合作)
分享到:
来源刊物:
影响因子:1.608 (2012)

×