The new digital electronics for the JET Neutron Profile Monitor: Performances and first experimental results
作者: Marco RivaBasilio EspositoDaniele MaroccoFrancesco BelliBrian Syme
作者单位: 1CCFE Culham, Culham Science Center, OX14 3DB, Abingdon, UK
2Associazione Euratom-ENEA sulla Fusione, via E. Fermi 45, C.P. 65, Frascati I-00044, Roma, Italy
刊名: Fusion Engineering and Design, 2011, Vol.86 (6), pp.1191-1195
来源数据库: Elsevier Journal
DOI: 10.1016/j.fusengdes.2011.02.038
关键词: Neutron–gamma discriminationFPGAReal-timeEmbedded LinuxJET
原始语种摘要: Abstract(#br)The 2D neutron emissivity profile is measured at JET by a set of NE213 liquid organic scintillators, located in two fan-shaped arrays of collimators with 10 horizontal and 9 vertical lines of sight. As the detectors are sensitive to neutron and gamma rays, pulse shape analysis is required for neutron/gamma discrimination. A digital architecture data-handling data acquisition and processing for the entire diagnostic has been developed by ENEA-Frascati and installed at JET during the 2009 campaign as a replacement of the existing analogue electronics. This paper describes the performances of the digital system and the first experimental results in the JET C27b campaign.
全文获取路径: Elsevier  (合作)
分享到:
来源刊物:
影响因子:0.842 (2012)

×