Predicting patient–prosthesis mismatch by aortic root evaluation before aortic valve replacement
作者: Koichi MaedaToru KurataniDaisuke YoshiokaKyongsun PakKazuo ShimamuraKoichi TodaYoshiki Sawa
作者单位: 1Department of Cardiovascular Surgery, Osaka University Graduate School of Medicine, Osaka, Japan
2Division of Biostatistics, Department of Data Management, Center for Clinical Research, National Center for Child Health and Development, Tokyo, Japan
刊名: The Journal of Thoracic and Cardiovascular Surgery, 2019, Vol.158 (1), pp.61-69.e4
来源数据库: Elsevier Journal
DOI: 10.1016/j.jtcvs.2018.11.103
关键词: Aortic valve stenosisPatient-prosthesis mismatchMultislice computed tomography
英文摘要: Abstract(#br)Objective(#br)This study aimed to assess the predictors of patient–prosthesis mismatch (PPM) after surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR) using preoperative computed tomography.(#br)Methods(#br)We enrolled 323 patients undergoing SAVR (n = 85) or TAVR (n = 238) for aortic stenosis. The end point was any degree of PPM (effective orifice area index <0.85 cm 2 /m 2 ). We assessed the predictors of PPM after SAVR or TAVR and compared the incidence of PPM between both arms. Furthermore, we compared the hemodynamic performance using the propensity score matching.(#br)Results(#br)The occurrence of PPM was significantly higher in the SAVR arm (24.7% vs 7.1%; P < .001). A small sinotubular junction was an independent predictor of PPM...
全文获取路径: Elsevier  (合作)