Macular versus Retinal Nerve Fiber Layer Parameters for Diagnosing Manifest Glaucoma
作者: Francesco OddoneErsilia LucenteforteManuele MichelessiStanislao RizzoSimone DonatiMariacristina ParravanoGianni Virgili
作者单位: 1Ophthalmology, Fondazione G.B. Bietti per lo studio e la ricerca in Oftalmolologia-IRCCS, Rome, Italy
2Department of Neurosciences, Psychology, Drug Research and Children's Health, University of Florence, Florence, Italy
3Department of Translational Surgery and Medicine, Eye Clinic, University of Florence, Florence, Italy
4Department of Surgical and Morphological Sciences, Section of Ophthalmology, University of Insubria, Varese-Como, Italy
刊名: Ophthalmology, 2016, Vol.123 (5), pp.939-949
来源数据库: Elsevier Journal
DOI: 10.1016/j.ophtha.2015.12.041
英文摘要: Topic(#br)Macular parameters have been proposed as an alternative to retinal nerve fiber layer (RNFL) parameters to diagnose glaucoma. Comparing the diagnostic accuracy of macular parameters, specifically the ganglion cell complex (GCC) and ganglion cell inner plexiform layer (GCIPL), with the accuracy of RNFL parameters for detecting manifest glaucoma is important to guide clinical practice and future research.(#br)Methods(#br)Studies using spectral domain optical coherence tomography (SD OCT) and reporting macular parameters were included if they allowed the extraction of accuracy data for diagnosing manifest glaucoma, as confirmed with automated perimetry or a clinician's optic nerve head (ONH) assessment. Cross-sectional cohort studies and case-control studies were included. The...
全文获取路径: Elsevier  (合作)
分享到:
来源刊物:
影响因子:5.563 (2012)

×
关键词翻译
关键词翻译
  • versus