原始语种摘要: Abstract(#br)In this work, a flow injection analysis (FIA) method was introduced for the determination of trace amounts of thiourea in tap water. This method is based upon the inhibition effect of thiourea on the reaction between meta-cresol purple (MCP) and potassium bromate catalyzed by bromide ions in a sulfuric acid medium. In the presence of thiourea, an induction period appears in the reaction system, and as a result, the absorbance of MCP increases at 525nm in the FIA manifold. The chemical and FIA variables are studied and optimized using the univariate and Simplex optimization methods. Under the optimum conditions, thiourea can be determined in the range of 0.100–13.0μgmL −1 . The limit of detection (3 σ ) for thiourea was...