Integration of Incinerator Plants and Utilization of Forest Biomass on the Basis of FIT
作者: HIDEO SUGAHARANAOKI KAMATAYUSUKE TODAMASAKAZU KATOKAZUYUKI AIHARA
作者单位: 1Graduate School, Tokyo Denki University Japan
2 Institute of Industrial Science the University of Tokyo Japan
刊名: Electrical Engineering in Japan, 2018, Vol.202 (1), pp.11-28
来源数据库: Wiley Journal
DOI: 10.1002/eej.22991
关键词: FITincinerator plantforest biomasswaste‐to‐energyrelay transportation
原始语种摘要: SUMMARY(#br)Feed‐in tariff (FIT) has been enforced in order to promote the utilization of renewable energy since 2012 in Japan. In consideration of FIT, we propose an integration plan for incinerator plants (IPs) with highly efficient power generation for the whole area of a prefecture. The plan includes disposal of forest biomass using the reserve capacity of IPs. The model prefecture's population is set to 1,200,000 and the proportion of the forested area is set to 70% of the model area based on data for northeastern Japan. The present 16 IPs are integrated into three new IPs. A relay transportation (RT) facility for waste is located at a decommissioned IP, and the waste from the area is transported to the new IP. In order to calculate the RT costs, an approximation formula for the RT...
全文获取路径: Wiley  (合作)