Possible malfunction in widely used methane sampler deserves attention but poses limited implications for supply chain emission estimates
作者: Ramón A. AlvarezDavid R. LyonAnthony J. MarcheseAllen L. RobinsonSteven P. Hamburg
刊名: Elementa, 2016
来源数据库: Elementa
DOI: 10.12952/journal.elementa.000137
关键词: methanenatural gas production
原始语种摘要: Estimates of methane emissions from natural gas production sites in the United States based on recent studies have been questioned due to possible malfunction of the Bacharach Hi Flow® Sampler (BHFS), the primary measurement instrument used for two out of five source types examined in those studies (equipment leaks and chemical injection pumps). Without assessing whether the BHFS malfunction occurred in those studies, we constrain the possible underestimation of emissions associated with the BHFS-based results by excluding potentially affected measurements. Assuming leak emission rates are similar for sites with low and high methane content, U.S. methane emissions from equipment leaks and chemical injection pumps in recent studies could be underestimated by up to 40–80% due to a...
全文获取路径: Elementa 
分享到:

×